MODEL: 60W SERIES
|
2010/04
|
||||
|
1.INTRODUCTION: |
|||||
|
THIS IS AN Flex ATX 100W POWER SUPPLY OF SPECIFIC Guidelines
1.0. |
|||||
|
|
|||||
|
2.AC INPUT: |
|||||
|
INPUT VOLTAGE RANGES |
100-240VAC |
||||
|
INPUT FREQUENCY |
50 TO 60 Hz. |
||||
|
INPUT CURRENT |
4A RMS MAX. FOR 115 VAC. 2A RMS MAX. FOR 230 VAC. |
||||
|
INRUSH CURRENT |
20A MAX. FOR 115 VAC COLD START. 40A MAX. FOR 230 VAC COLD START. |
||||
|
POWER FACTOR CORRECTION |
□ACTIVE □ PASSIVE ■ NONE |
CIRCUIT |
|||
|
|
|||||
|
3. DC OUTPUT: |
|||||
|
MODEL |
PP-12VDC-9B |
PP-12VDC-5B |
|
||
|
VOLTAGE |
+12V |
+12V |
|
||
|
TOLERANCE |
+ /
-5% |
+ /
-5% |
|
||
|
MAX. CURRENT |
5A |
5A |
|
||
|
MIN. CURRENT |
0A |
0A |
|
||
|
EACH PORT CURRENT |
1A |
2A |
|
||
|
RIPPLE
& NOISE |
120mV |
120mV |
|
||
|
LINE
REGULATION |
+ /
-1% |
+ /
-1% |
|
||
|
LOAD
REGULATION |
+ /
-5% |
+ /
-5% |
|
||
|
TOTAL
OUTPUT POWER |
60W MAX. |
||||
|
|
|||||
|
4 .ELECTRICAL SPECIFICATIONS: |
|||||
|
EFFICIENCY |
80 % MIN. AT 100%
LOADING. |
||||
|
RISE TIME |
20mS MAX. |
||||
|
HOLD UP TIME |
MIN 17 ms AT FULL LOAD AND NOMINAL INPUT VOLTAGE. |
||||
|
STABILITY |
+ / -0.5% AFTER 24 HOURS WARM UP. |
||||
|
OVERSHOOT |
10% MAX.
ABOVE THE NORMAL VOLTAGE. |
||||
|
LEAKAGE CURRENT |
3.5Ma MAX. AT 230VAC. |
||||
|
|
|||||
|
5 .OUTPUT PROTECTION: |
|||||
|
SHORT-CIRCUIT PROTECTION |
ALL OUTPUT EQUIPPED WITH
SHORT CIRCUIT PROTECTION. |
||||
|
OVERCURRENT PROTECTION |
150% MAX. |
||||
|
|
|||||
|
6 .ENVIRONMENTAL: |
|||||
|
OPERATING TEMPERATURE |
0℃ TO +40℃. |
||||
|
OPERATING HUMIDITY |
20% TO 90% RH. |
||||
|
OPERATING ALTITUDE |
0 TO 10,000 ft |
||||
|
STORAGE TEMPERATURE |
-20℃ TO +85℃. |
||||
|
STORAGE HUMIDITY |
10% TO 95% RH. |
||||
|
STORAGE ALTITUDE |
0 TO 50,000 ft |
||||
|
VIBRATION |
10-500Hz, 2G 10MIN/TCYLE ,PERIOD FOR 60MIN.
EACH AXES. |
||||
|
COOLING |
40mm BALL BEARING FAN |
||||
|
|
|||||
|
7.RELIABILITY: |
|||||
|
MTBF(Mean Time Between Failures) |
100K HOURS AT MAX. LOAD , NORMAL LINE AND 25℃ |
||||
|
|
|||||
|
8.MECHANICAL: |
|||||
|
PHYSICAL DIMENSIONS |
165(L) x 81.5(W) x 43(H)mm |
||||
|
AC CONNECTOR |
IEC 320 C14 TYPE |
||||
|
DC CONNECTORS |
TERMINAL BLOCK |
||||
|
|
|||||
|
9. SAFETY STANDARDS |
MEET PENDING IEC 60950 |
||||
|
|
|||||
|
10.EMC STANDARDS |
MEET PENDING EN55022 ,EN55024 (IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11) |
||||
|
|
|||||
|
11.HI POT TEST |
IEC 61000-3-2, IEC 61000-3-3) |
||||
|
INPUT TO OUTPUT |
1500VAC FOR 1 SEC. |
||||
|
INPUT
TO FRAME GROUND |
1500VAC FOR 1 SEC. |
||||
|
|
|||||
|
12.INSOLATION RESISTANCE |
|||||
|
INPUT TO OUTPUT |
500VDC / 50 M Ohms. |
||||
|
INPUT TO FRAME GROUND |
500VDC / 50 M Ohms. |
||||