MODEL:100W SERIES
|
2010/04
|
|
1.INTRODUCTION:
|
|
THIS IS AN Flex ATX 100W POWER SUPPLY OF SPECIFIC Guidelines
1.0.
|
|
|
|
2.AC INPUT:
|
|
INPUT VOLTAGE RANGES
|
100-240VAC
|
|
INPUT FREQUENCY
|
50 TO 60 Hz.
|
|
INPUT CURRENT
|
5A RMS MAX. FOR 115 VAC.
|
|
2.5A RMS MAX. FOR 230 VAC.
|
|
INRUSH CURRENT
|
25A
MAX. FOR 115 VAC COLD START.
|
|
50A MAX.
FOR 230 VAC COLD START.
|
|
POWER FACTOR CORRECTION
|
□ACTIVE □ PASSIVE
■ NONE
|
CIRCUIT
|
|
|
|
3.DC
OUTPUT:
|
|
MODEL
|
PP-12VDC-5C
|
PP-18VDC-5C
|
PP-24VDC-5C
|
PP-36VDC-5C
|
|
VOLTAGE
|
+12VDC
|
+18VDC
|
+24VDC
|
+36VDC
|
|
TOLERANCE
|
+ /
-5%
|
+ /
-5%
|
+ /
-5%
|
+ /
-5%
|
|
MAX. CURRENT
|
9A
|
6A
|
4.5A
|
3A
|
|
MIN.
CURRENT
|
0A
|
0A
|
0A
|
0A
|
|
EACH PORT CURRENT
|
1.7A
|
1.0A
|
0.8A
|
0.5A
|
|
RIPPLE
& NOISE
|
120mV
|
180mV
|
240mV
|
360mV
|
|
LINE
REGULATION
|
+ /
-1%
|
+ /
-1%
|
+ /
-1%
|
+ /
-1%
|
|
LOAD
REGULATION
|
+ /
-5%
|
+ /
-5%
|
+ /
-5%
|
+ /
-5%
|
|
TOTAL
OUTPUT POWER
|
108W MAX.
|
|
|
|
4.ELECTRICAL SPECIFICATIONS:
|
|
EFFICIENCY
|
80 % MIN. AT 100%
LOADING.
|
|
RISE TIME
|
20mS MAX.
|
|
HOLD UP TIME
|
MIN 17 ms AT FULL LOAD AND
NOMINAL INPUT VOLTAGE.
|
|
STABILITY
|
+ / -0.5% AFTER 24 HOURS
WARM UP.
|
|
OVERSHOOT
|
10% MAX. ABOVE THE NORMAL VOLTAGE.
|
|
LEAKAGE CURRENT
|
3.5Ma MAX. AT 230VAC.
|
|
FAN NOISE KILLER
|
FAN SPEED CONTRAL FUNCTION INSIDE
|
|
|
|
5.OUTPUT PROTECTION:
|
|
SHORT-CIRCUIT PROTECTION
|
ALL OUTPUT EQUIPPED WITH SHORT CIRCUIT PROTECTION.
|
|
OVERCURRENT PROTECTION
|
150% MAX.
|
|
OVER VOLTAGE PROTECTION
|
+12V OUTPUT:
13.2V MAX
|
|
+18V OUTPUT:
19.8V MAX
|
|
+24V OUTPUT:
26.4V MAX
|
|
+36V OUTPUT:
39.6V MAX
|
|
|
|
6.ENVIRONMENTAL:
|
|
OPERATING TEMPERATURE
|
0℃
TO +40℃.
|
|
OPERATING HUMIDITY
|
20% TO 90% RH.
|
|
OPERATING ALTITUDE
|
0
TO 10,000 ft
|
|
STORAGE TEMPERATURE
|
-20℃
TO +85℃.
|
|
STORAGE HUMIDITY
|
10% TO 95% RH.
|
|
STORAGE ALTITUDE
|
0
TO 50,000 ft
|
|
VIBRATION
|
10-500Hz, 2G 10MIN/TCYLE ,PERIOD FOR 60MIN. EACH AXES.
|
|
COOLING
|
40mm BALL BEARING FAN
|
|
|
|
7.RELIABILITY:
|
|
MTBF (Mean Time
Between Failures)
|
100K HOURS AT MAX. LOAD ,
NORMAL LINE AND 25℃
|
|
|
|
8.MECHANICAL:
|
|
PHYSICAL DIMENSIONS
|
165(L) x 81.5(W) x 43(H)mm
|
|
AC CONNECTOR
|
IEC 320 C14 TYPE
|
|
DC CONNECTORS
|
TERMINAL BLOCK
|
|
|
|
9.SAFETY STANDARDS
|
MEET
|
PENDING IEC 60950
|
|
10.EMC
STANDARDS
|
MEET
|
PENDING EN55022 ,EN55024 (IEC 61000-4-2,
|
|
IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
|
|
IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11)
|
|
|
|
11.HI POT TEST
|
IEC 61000-3-2, IEC
61000-3-3)
|
|
INPUT TO OUTPUT
|
1500VAC FOR 1
SEC.
|
|
INPUT TO FRAME GROUND
|
1500VAC FOR 1
SEC.
|
|
|
|
12.INSOLATION RESISTANCE:
|
|
INPUT TO OUTPUT
|
500VDC / 50 M Ohms.
|
|
INPUT TO FRAME GROUND
|
500VDC / 50 M Ohms.
|
|
|
|
|
|
|
|
|
|